Shrnutí obsahu

Strany 1 - Document Number 3PCI-4310m

Document Number 3PCI-4310m MMuullttii--IInntteerrffaaccee PPCCII BBuuss SSeerriiaall CCaarrddss ((RRSS--223322 // RRSS--442222 // R

Strany 2

General Information 4 Chapter 1 Document Number 3PCI-4310m Specifications OS Supported Windows XP, Windows 2008 Server (32/64 bit), Windows Vista (3

Strany 3

Serial Card Setup Document Number 3PCI-4310m Chapter 2 5 CChhaapptteerr 22:: SSeerriiaall CCaarrdd SSeettuupp The following Serial Card

Strany 4

Serial Card Setup 6 Chapter 2 Document Number 3PCI-4310m Overview of Operational Modes RS-232 Mode In RS-232 Mode MIport serial ports function as bu

Strany 5

Serial Card Setup Document Number 3PCI-4310m Chapter 2 7 Operating Mode Selection The hardware address and IRQ for the serial card is set by t

Strany 6

Serial Card Setup 8 Chapter 2 Document Number 3PCI-4310m multipoints) the transmitter can be enabled all the time. Placing the middle DIP switch in

Strany 7 - Features

Serial Card Setup Document Number 3PCI-4310m Chapter 2 9 DIP Switch 1 (RS-422/485 only) The top DIP switch (1) configures the port for RS-48

Strany 8 - MIport Models and Features

Serial Card Setup 10 Chapter 2 Document Number 3PCI-4310m Installing the Serial Card CAUTION: This is an Electrostatic Sensitive Device. Use ESD pr

Strany 9

Driver Software Installation Document Number 3PCI-4310m Chapter 3 11 CChhaapptteerr 33:: DDrriivveerr SSooffttwwaarree IInnssttaallllaatti

Strany 10 - Specifications

Driver Software Installation 12 Chapter 3 Document Number 3PCI-4310m Pre-Installation Steps 1. Configure the port(s) on the card for the desired mo

Strany 11 - Initial Configuration

Driver Software Installation Document Number 3PCI-4310m Chapter 3 13 You may want to check to verify that the new B&B COM ports are now av

Strany 12 - RS-485 Mode

Document Number 3PCI-4310m International Headquarters B&B Electronics Mfg. Co. Inc. 707 Dayton Road Ottawa, IL 61350 USA Phone (815) 433-51

Strany 13 - Operating Mode Selection

Setting Driver Options 14 Chapter 4 Document Number 3PCI-4310m CChhaapptteerr 44:: SSeettttiinngg DDrriivveerr OOppttiioonnss Configuring Por

Strany 14 - 2-wire RS-485 Mode

Setting Driver Options Document Number 3PCI-4310m Chapter 4 15 Figure 8. Advanced Port Settings Setting the FIFO Buffers MIport cards use U

Strany 15

Setting Driver Options 16 Chapter 4 Document Number 3PCI-4310m Note: For proper operation the DIP switches on the PCI card must be set for the same

Strany 16 - Installing the Serial Card

Setting Driver Options Document Number 3PCI-4310m Chapter 4 17 Figure 9. Changing the COM Port Name/Number 2. After selecting a new COM nam

Strany 17

Installing Linux Driver Software 18 Chapter 5 Document Number 3PCI-4310m CChhaapptteerr 55:: IInnssttaalllliinngg LLiinnuuxx DDrriivveerr SSoo

Strany 18 - Pre-Installation Steps

Installing Linux Driver Software Document Number 3PCI-4310m Chapter 5 19 make -C /lib/modules/2.6.32-24-generic/build M=/home/username/MIport-

Strany 19

Installing Linux Driver Software 20 Chapter 5 Document Number 3PCI-4310m username@computer$ dmesg | grep MIport  [ 271.828182] B&B Electroni

Strany 20 - Configuring Port Settings

Installing Linux Driver Software Document Number 3PCI-4310m Chapter 5 21 Ubuntu 10.04 Server (32-bit and 64-bit) 1. Determine which version of

Strany 21 - Setting the FIFO Buffers

Installing Linux Driver Software 22 Chapter 5 Document Number 3PCI-4310m username@computer$ sudo apt-get install linux-headers-2.6.32-21-server 

Strany 22

Installing Linux Driver Software Document Number 3PCI-4310m Chapter 5 23 11. Change the current working directory to where the MIport driver s

Strany 23

Document Number 3PCI-4310m Table of Contents i CAUTION: This is an Electrostatic Sensitive Device. Use ESD precautions for safe handling. B

Strany 24

Installing Linux Driver Software 24 Chapter 5 Document Number 3PCI-4310m Searching for MIport driver in: ... The MIport driver was found in: ... Th

Strany 25

Removing Drivers, Ports and Cards Document Number 3PCI-4310m Chapter 6 25 CChhaapptteerr 66:: RReemmoovviinngg DDrriivveerrss,, PPoorrttss

Strany 26

Removing Drivers, Ports and Cards 26 Chapter 6 Document Number 3PCI-4310m Figure 10. Finding the INF files in Windows Explorer To find these fil

Strany 27

Removing Drivers, Ports and Cards Document Number 3PCI-4310m Chapter 6 27 Figure 11. Setting the Folder Options to Display Hidden Files 3. D

Strany 28

RS-232 Connections/Operation 28 Chapter 7 Document Number 3PCI-4310m CChhaapptteerr 77:: RRSS--223322 CCoonnnneeccttiioonnss//OOppeerraattiioonn

Strany 29

RS-232 Connections/Operation Document Number 3PCI-4310m Chapter 7 29 RS-232 Signal Designations The primary RS-232 signals are TD (transmit) an

Strany 30

RS-232 Connections/Operation 30 Chapter 7 Document Number 3PCI-4310m The standard specifies that RS-232 inputs accept voltage levels between –3 volt

Strany 31 - Uninstalling the COM ports

RS-422/ 485 Connections/Operation Document Number 3PCI-4310m Chapter 8 31 CChhaapptteerr 88:: RRSS--442222//448855 CCoonnnneeccttiioonnss//O

Strany 32

RS-422/485 Connections/Operation 32 Chapter 8 Document Number 3PCI-4310m RS-422/485 Differential Signals In RS-422 and RS-485 interfaces signals ar

Strany 33

RS-422/ 485 Connections/Operation Document Number 3PCI-4310m Chapter 8 33 RS-422 Limitations The limitation of RS-422 operation is that only on

Strany 34

ii Table of Contents Document Number 3PCI-4310m TTaabbllee ooff CCoonntteennttss TABLE OF CONTENTS ...

Strany 35 - RS-232 Signal Designations

RS-422/485 Connections/Operation 34 Chapter 8 Document Number 3PCI-4310m Figure 17. Setting RTS Control for RS-485 The RS-485 mode is set by conf

Strany 36 - RTS Control In RS-232 Mode

RS-422/ 485 Connections/Operation Document Number 3PCI-4310m Chapter 8 35 It is important to maintain the Mark state for all RS-485 receivers w

Strany 37 - RS-422/485 Mode

RS-422/485 Connections/Operation 36 Chapter 8 Document Number 3PCI-4310m Figure 19. Termination and Bias Resistor Placement Note: For more informa

Strany 38 - RS-422 Operation

RS-422/ 485 Connections/Operation Document Number 3PCI-4310m Chapter 8 37 485, using the A connection for “+” and the B for “-“. In such cases,

Strany 39 - RS-485 Operation

RS-422/485 Connections/Operation 38 Chapter 8 Document Number 3PCI-4310m 4-Wire RS-485 Connection In a 4-wire RS-485 system, each receive line conne

Strany 40 - RS-485 Network Biasing

DIP Switch / Mode Settings Document Number 3PCI-4310m Appendix A A -1 CChhaapptteerr 99:: TTrroouubblleesshhoooottiinngg MMIIppoorrtt CCaa

Strany 41

DIP Switch / Mode Settings A-2 Appendix A Document Number 3PCI-4310m 2. Make sure you have RTS Control set to the correct mode: Normal for RS-23

Strany 42 - 2-Wire RS-485 Connections

DIP Switch / Mode Settings Document Number 3PCI-4310m Appendix A A -1 3. To check 2-wire RS-485 RS-422 or 4-wire RS-485 Loopback Connections, y

Strany 43

DIP Switch / Mode Settings A-4 Appendix A Document Number 3PCI-4310m AAppppeennddiixx AA:: DDIIPP SSwwiittcchh//MMooddee SSeettttiinnggss S

Strany 44 - 4-Wire RS-485 Connection

DIP Switch / Mode Settings Document Number 3PCI-4310m Appendix A A -1 stated when not sending data, allowing other transmitters on the communica

Strany 45 - RS-422/485 Operation

Document Number 3PCI-4310m Table of Contents iii Uninstalling the MIport Card ...

Strany 46 - Checking the MIport Card

DIP Switch / Mode Settings A-6 Appendix A Document Number 3PCI-4310m stated when not sending data, allowing other transmitters on the communicati

Strany 47

Connector Pinouts Document Number 3PCI-4310m Appendix B B -1 AAppppeennddiixx BB:: CCOONNNNEECCTTOORR PPIINNOOUUTTSS RS-232 Pinouts Name Des

Strany 48

Connector Pinouts B-2 Appendix B Document Number 3PCI-4310m RS-422/485 Pinouts Name Description Direction DB-9M Pin RDA(−) Receive Data A (-) Input

Strany 49

Connector Pinouts Document Number 3PCI-4310m Appendix B B -1 Figure 31. 2-Wire RS-485 Wiring

Strany 51 - RS-232 Pinouts

Document Number 3PCI-4310m Appendix D D-1 AAppppeennddiixx CC:: TTrroouubblleesshhoooottiinngg WWiitthh CCoommTTeesstt ComTest is a simple 3

Strany 52 - RS-422/485 Pinouts

Declaration of Conformity D-2 Appendix D Document Number 3PCI-4310m Figure 32. Loading ComTest 2. Run Setup.exe to install ComTest on your progra

Strany 53 - Connector Pinouts

Document Number 3PCI-4310m Appendix D D-1 Figure 33. RS-232 Loopback w/Handshaking Connections 2. From the Windows Desktop click Start → Programs

Strany 54

iv Table of Contents Document Number 3PCI-4310m DIP Switch 1 (RS-422/485 only)...

Strany 55 - Installing ComTest

General Information Document Number 3PCI-4310m Chapter 1 1 CChhaapptteerr 11:: GGeenneerraall IInnffoorrmmaattiioonn Introduction MIport

Strany 56

General Information 2 Chapter 1 Document Number 3PCI-4310m MIport Models and Features Model Number Ports Interface Connectors 3PCIOU1 1 RS-232/422

Strany 57

General Information Document Number 3PCI-4310m Chapter 1 3 Model Number Ports Interface Connectors 3PCIU2 2 RS-232/422/485 2 x DB-9 male 3