B&B Electronics DSCLP-100 Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Karty / adaptéry rozhraní B&B Electronics DSCLP-100. B&B Electronics DSCLP-100 Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 38
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
DSCLP/SSCLP-100
Two Channel Low Profile RS-232
Asynchronous Communications Adapter
for PCI bus
User's Manual
QUATECH, INC. TEL: (330) 655-9000
5675 Hudson Industrial Parkway FAX: (330) 655-9010
Hudson, Ohio 44236 http://www.quatech.com
1 DSCLP/SSCLP-100 User's Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 37 38

Shrnutí obsahu

Strany 1 - User's Manual

DSCLP/SSCLP-100Two Channel Low Profile RS-232 Asynchronous Communications Adapterfor PCI busUser's ManualQUATECH, INC. TEL: (330) 655-90005675 Hu

Strany 2

4 Address Map and Special RegistersThis chapter explains how the two UARTs and special registers areaddressed, as well as the layout of those register

Strany 3

4.2 Enabling the Special RegistersThe DSCLP-100 contains two unique registers, an Interrupt StatusRegister and an Options Register. These registers a

Strany 4 - Declaration of Conformity

4.4 Options RegisterThe Options Register allows software to identify the DSCLP-100 as aQuatech Enhanced Serial Adapter. It also allows software to se

Strany 5

4.4.2 Clock Rate MultiplierA standard RS-232 serial port operates at a clock speed of 1.8432 MHz.In order to achieve higher data rates, Quatech Enhanc

Strany 6 - 1 General Information

5 Windows Configurations5.1 Windows Millennium 1. After inserting the DSCLP-100 for the first time the "Add New HardwareWizard" will b

Strany 7 - 2 Hardware Configuration

5.2 Windows 20001. After inserting a DSCLP-100 for the first time, the "Add New HardwareWizard will appear at start up. Click the "OK"

Strany 8

5.3 Windows 981. After inserting a DSCLP-100 for the first time, the "Add New HardwareWizard will appear at start up. Click the "Next"

Strany 9 - 3 Hardware Installation

4. The following dialog box will display the appropriate INF file on thedisk in the drive. Click the "Next" button. 5. Window will co

Strany 10

5.5 Using the "New Hardware Found" WizardThe following instructions provide step-by-step instructions on installingthe DSCLP-100 in Windows

Strany 11 - 4.3 Interrupt Status Register

NOTE:You may be able to skip this step if you are certain that your system has the latestversion of these files installed. If you do not have your Wi

Strany 12 - 4.4 Options Register

WARRANTY INFORMATIONQuatech, Inc. warrants the DSCLP-100 or SSCLP-100 to be free of defects for five (5) years from the date of purchase. Qua

Strany 13 - 4.4.2 Clock Rate Multiplier

5.6 Viewing Resources with Device ManagerThis discussion applies equally to Windows 95/98/ME and 2000/XP.The following instructions provide step-by-s

Strany 14 - 5 Windows Configurations

Figure 12--- Windows Device Manager6. The DSCLP-100 serial ports are also listed under the group Ports (COMand LPT). Windows 95 does not assign COM1

Strany 15 - 5.2 Windows 2000

Figure 13 --- Windows Device Manager9. Use the Logical COM Port names to access the serial ports on yourDSCLP-100 through your software applications.

Strany 16 - 5.3 Windows 98

5.6.1 Changing Resource Settings with Device Manager1. Start the Windows 95/98/ME Device Manager.2. Double click on the hardware class Multi-Port Seri

Strany 17 - 5.4 Windows 95

4. Open the Properties dialog for the DSCLP-100 device, then click theResources tab to view the Input/Output Range and Interrupt Requestresource alloc

Strany 18

The X2 clock mode locks the ports hardware clock at double the standardrate. The baud rate the port runs at willalways be double the rate requested

Strany 19 - 10. Installation is complete

The X8 clock mode locks the portshardware clock at eight times thestandard rate. The baud rate the portruns at will always be eight times therate req

Strany 20

8. Click the "Port Settings" tab and then click the "Advanced" button.The DSCLP-100 driver will display a custom Advanced Port Set

Strany 21

28 DSCLP/SSCLP-100 User's Manual

Strany 22

6 Other Operating SystemsDevice drivers for Windows NT and OS/2 are also available for theDSCLP-100. The board can be used under DOS and other operat

Strany 23

 2006, Quatech, Inc.NOTICEThe information contained in this document cannot be reproduced in anyform without the written consent of Quatech, Inc. Li

Strany 24

6.3.1 QTPCI.EXEQuatech's "QTPCI" utility supplies the information required whenmodifying the serial port settings of the application.

Strany 25

Figure 15 shows the Expert Mode display for the DSCLP-100 after the"Q" key has been pressed. The information from the Basic Mode display is

Strany 26

7 External ConnectionsRS-232-C devices are classified by their function as either Data TerminalEquipment (DTE) or Data Communication Equipment (DCE).

Strany 27

The DSCLP-100 is a DTE device which connects to peripheral equipmentthrough a single male D-25 connector, or using the adapter cable, two male D-9conn

Strany 28

8 PCI Resource MapListed below are the PCI resources used by the DSCLP-100. Suchinformation may be of use to customers writing their own device drive

Strany 29 - 6 Other Operating Systems

9 SpecificationsBus interface: PCI, 32-bit bus, Universal Voltage SignalingIBM-compatible computersDimensions: approx. 5.0" x 3.7"Serial por

Strany 30 - 6.3.1 QTPCI.EXE

4800430033001570800115.2200016301100900330230.41100900670430100460.8470430300100N/A921.625%transtime20%transtime15%transtime10% transtime4% transtimeM

Strany 31

10 TroubleshootingListed here are some common problems and frequent causes of thoseproblems. If the information here does not provide a solution, con

Strany 32 - 7 External Connections

DSCLP/SSCLP-100 User's Manual Revision 1.05November 2006P/N: 940-0179-1051 DSCLP/SSCLP-100 User's Manual

Strany 33

Declaration of ConformityManufacturer's Name: Quatech Inc.Manufacturer's Address: 5675 Huson Industrial ParkwayAkron, Ohio 44236 (USA)Applic

Strany 34 - 8 PCI Resource Map

Table of Contents3910 Troubleshooting...379 Specifications...368 PCI Resource Map...

Strany 35 - 9 Specifications

1 General InformationThe Quatech, Inc. DSCLP-100 (two-port) and SSCLP-100 (one-port)provide RS-232 asynchronous serial communication interfaces for Lo

Strany 36

2 Hardware ConfigurationThe DSCLP-100 is automatically configured at boot time by thecomputer's BIOS or operating system. There are no required

Strany 37 - 10 Troubleshooting

2.3 Force High-Speed UART Clock (X2 or X4, J4-J5)These jumpers force an increase of the UART input clock frequency by afactor of two or four. This fe

Strany 38

3 Hardware Installation1. Turn off the power of the computer system in which the DSCLP-100 is tobe installed.2. Remove the system cover according to t

Komentáře k této Příručce

Žádné komentáře