Configuring the Serial Port Settings
Use the Tab key to advance to the baud rate, Data/Parity/Stop bits, and Flow
control section of the menu. Use the arrow keys to advance to a selection that
matches the connected serial device. The serial port settings must match the
connected serial device when using TCP/UDP socket programs. If the ESP
Virtual COM driver is used the application software will control the ESP901
serial port setting.
Configuring the Mode of Operation
It must first be decided what Operation Mode is going to fit the application.
Connection mode has 2 options, client and server.
When using the Virtual COM port feature select Server
When using socket software select Server
When using paired connection mode set one to server and one to
client.
For more details see section 8, Communication Modes.